Cummins 440kW Diesel Generator Set Technical Specifications

ParameterValueParameterValue
Unit ModelJHGC-440Exhaust Back Pressure (kPa)10
Fan Power (kW)16.7Exhaust Temperature (°C)490
Prime Power (kW)440Exhaust Flow (m³/min)106.5
Airflow (m³/min)810Type de carburantDomestic No. 0 Diesel (at normal temp)
Standby Power (kW)484Engine Oil Capacity (L)50
Gas Flow (m³/min)34.26Coolant Capacity (L)107.5
Rated Capacity (kVA)550Weight (kg)1633 (engine), 5300 (unit)
Rated Speed (RPM)1500Generator ModelHengguan JHG-440
Rated Voltage (V)400Unit Dimensions (L×W×H, mm)3510×1500×2055
Rated Current (A)793.76Prime Power (kW)440
Rated Frequency (Hz)50Standby Power (kW)484
Power Factor0.8Engine ModelCummins KTAA19-G5
Phase Number3Engine Rated Power (kW)470
Generator Efficiency (%)93.5Engine Standby Power (kW)555
Generator ExcitationBrushless PMGEngine Type4-stroke, turbocharged
Voltage RegulationAVRCylinders/Arrangement6 / In-line
Starting MethodElectric StartBore × Stroke (mm)159 × 159
Fuel Injection SystemPT Direct InjectionDisplacement (L)19
Governor TypeElectronicCompression Ratio13.9:1
Full-Load Fuel Consumption (g/kWh)204Cooling SystemClosed-circuit water cooling
Insulation ClassHProtection RatingIP21
Temperature Rise ClassHEngine Weight (kg)1390

Key Features:

  • Engine: Cummins KTAA19-G5, 6-cylinder turbocharged, 19L displacement
  • Generator: Hengguan JHG-440, brushless PMG excitation, 93.5% efficiency
  • Performance: 440kW prime power / 484kW standby, 400V/50Hz, 0.8 PF
  • Cooling & Exhaust: Closed-loop water cooling, 490°C max exhaust temp
  • Compliance: Meets ISO 8528 standards for diesel generator sets

(Note: Specifications are subject to change based on configuration and regional standards.)


Formatting Notes:

  • Bilingual Consistency: Technical terms (e.g., “turbocharged” = 涡轮增压) follow industry standards.
  • Unit Standardization: Uses ISO units (kPa, °C, L) for global readability.
  • Structural Clarity: Tabular layout groups related parameters (power, engine, generator) for quick reference.
  • Brand Retention: “Hengguan” and “Cummins” remain untranslated as proper nouns.

如需调整格式或补充细节,请告知!

Article précédent

Groupe électrogène diesel d'occasion de la série Deutz

Article suivant

Les générateurs d'occasion permettent d'économiser de l'argent et du stress

fr_FRFrench